File Name
DT Series Dataloggers Installation Guidelines
Resource Type
ManualLanguage | Version | Download |
---|---|---|
English | ELM0089B |
The DT2011B Single Channel Vibrating Wire Data Logger is a low cost, battery powered data logger, designed for reliable, unattended monitoring of a single vibrating wire sensor and thermistor.
The DT2011B Single Channel Vibrating Wire Data Logger is a low-cost, battery-powered data logger, designed for reliable, unattended monitoring of a single vibrating wire sensor and thermistor.
It is a purpose-built logger ideal for remote locations or instruments that require frequent reliable data recording. It connects to all vibrating wire sensors including piezometers, crack meters and strain gauges; however, the DT2011B Single Channel Vibrating Wire Data Logger will not connect to vibrating wire sensors with auto resonant circuitry.
Vibrating wire sensors have unique advantages in geotechnical applications, as the frequency output of the gauge is immune to external electrical noise, able to tolerate wet wiring without signal degradation, and able to transmit the signal up to 1.6 kilometers without loss.
Data logger setup and data collection is done using a laptop. RST’s DT Logger Host Software is also included.
The DT2011B can also be equipped with an optional radio antenna (see photos) to incorporate it into an RSTAR or DT LINK wireless system (see separate brochures). RST’s RSTAR system uses wireless technology to provide automated data acquisition and DT LINK allows wireless collection of data logger data in hard to access areas.
ITEM | SPECIFICATION |
Frequency Accuracy | 0.01% Full Scale |
Resolution | 1 part in 65,000 |
Memory Records | Up to 600,000 records including: time, frequency , temperature |
Power Source | Lithium compact or standard cell battery (NOTE: standard cell required for radio use) |
Battery Life | Up to 4 years (assuming 1 hour reading frequency) depending on temperature and use (radio or non-radio) |
Communication | USB Type B connector (radio optional) |
Dimensions | 190 x 75 x 55 mm (7.48 x. 2.95 x 2.17 in.) |
Temperature Range | -40°C to 60°C (-40° to 140°F) |
Enclosure | NEMA 4X (IP66) |
ITEM | SPECIFICATION |
Memory Size | 4MB |
Data Transfer | 2,300 data points per second |
Interval Mode | 2 seconds to 1 day |
Variable Rate Mode | 16 user-programmable sampling rates |
Time Format | Month / day / year Hour / minute / second |
Memory Full Behaviour | “Wrap around” or “fill & stop” option |
DT2011B: Single Channel Vibrating Wire Data Logger is commonly used where reliable, unattended monitoring of a single vibrating wire sensor including piezometers, crack meters and strain gauges is required.
View illustrations on how this is used for:
ITEM | PART # |
DT2011B Single Channel Vibrating Wire Data Logger | DT2011B |
Cable Gland Nut Wrench | DT100 |
Pole Mount Kit | DT20XX-M1 |
4” Secondary Enclosure | DT2011-SE |
RSTAR L900 – automated wireless data collection |
DT2011B DTLINK – wireless data collection |
DT Series Dataloggers Installation Guidelines
Language | Version | Download |
---|---|---|
English | ELM0089B |
DT Series Dataloggers Maintenance and Service Guidelines
Language | Version | Download |
---|---|---|
English | ELM0088B |
DT Logger Host Instruction Manual PC Platform
Language | Version | Download |
---|---|---|
English | ELM0080R |
DT Logger Host Instruction Manual – Mobile Platform
Language | Version | Download |
---|---|---|
English | ELM0081D |
DT2011B Single Channel Vibrating Wire Data Logger
Language | Version | Download |
---|---|---|
English | ELB0016Y | |
Portuguese | ELB0089A | |
Spanish | ELB0083B |
Firmware Updates for PC (Logger Firmware Update.exe)
The following loggers firmware can be updated using this utility:
DT2011, DT2011B, DT2055B, DT2040, DT4205, RTU, DTL201B, DT2485, DT2350, GAA2820, DTSAA
Only download and install the firmware for your device if you have been instructed by a representative from RST Instruments Ltd. Any unnecessary installation of the firmware can cause unexpected device behaviour.
Please contact RST Technical Support for more information:
Email: [email protected]
Telephone: 604-540-1100
Language | Version | Download |
---|---|---|
English | 1.25 |
DT Logger Host Software for PC
Unzip the ZIP file once it is downloaded.
From the extracted files, double click on the “.exe” file.
Follow the instructions to install.
Language | Version | Download |
---|---|---|
English | 1.20.0 | |
English | Release Notes |
DT Logger Host Software for Nautiz X8
Language | Version | Download |
---|---|---|
English | 2.70 |
DT Logger Host for FieldPC
INSTALLATION NOTES:
Unzip the ZIP file once it is downloaded.
From the extracted files, open file titled “Installing Mobile DT Logger Host Software.txt”.
Follow instructions in the file.
Language | Version | Download |
---|---|---|
English | 2.67 |
8-inch Secondary Enclosure Installation Guide
Language | Version | Download |
---|---|---|
English | ELI0095A |
I’m very happy with the quality of the instrumentation and technical support from RST, as always. They worked with us from the initial stages of the project to ensure that we were fully prepared and equipped to use the RSTAR network for the first time. They delivered everything within the tight project time frame to ensure that there were no delays on site, and the submersible tilt meters looked like new even after over twelve months of being submerged in Thames water!
-Richard Lipscombe, BEng (Hons), Director & Principle Consultant - RL Geotechnical Ltd