DT2011B: Single Channel Vibrating Wire Data Logger

Category:

The DT2011B Single Channel Vibrating Wire Data Logger is a low cost, battery powered data logger, designed for reliable, unattended monitoring of a single vibrating wire sensor and thermistor.

Quantity

Add to Quote

Product Features

  • Battery powered for remote sites
  • Compatibility with all VW sensors
  • 100-year memory backup
  • User-friendly software
  • Compatible with most spreadsheet softwares

Overview

The DT2011B Single Channel Vibrating Wire Data Logger is a low-cost, battery-powered data logger, designed for reliable, unattended monitoring of a single vibrating wire sensor and thermistor.

It is a purpose-built logger ideal for remote locations or instruments that require frequent reliable data recording. It connects to all vibrating wire sensors including piezometers, crack meters and strain gauges; however, the DT2011B Single Channel Vibrating Wire Data Logger will not connect to vibrating wire sensors with auto resonant circuitry.

Vibrating wire sensors have unique advantages in geotechnical applications, as the frequency output of the gauge is immune to external electrical noise, able to tolerate wet wiring without signal degradation, and able to transmit the signal up to 1.6 kilometers without loss.

Data logger setup and data collection is done using a laptop. RST’s DT Logger Host Software is also included.

The DT2011B can also be equipped with an optional radio antenna (see photos) to incorporate it into an RSTAR or DT LINK wireless system (see separate brochures). RST’s RSTAR system uses wireless technology to provide automated data acquisition and DT LINK allows wireless collection of data logger data in hard to access areas.


DT2011B: Single Channel Vibrating Wire Data Logger Specifications

ITEM SPECIFICATION
Frequency Accuracy 0.01% Full Scale
Resolution 1 part in 65,000
Memory Records Up to 600,000 records including: time, frequency
, temperature
Power Source Lithium compact or standard cell battery
(NOTE: standard cell required for radio use)
Battery Life Up to 4 years (assuming 1 hour reading frequency)
depending on temperature and use (radio or non-radio)
Communication USB Type B connector (radio optional)
Dimensions 190 x 75 x 55 mm (7.48 x. 2.95 x 2.17 in.)
Temperature Range -40°C to 60°C (-40° to 140°F)
Enclosure NEMA 4X (IP66)

 

MEMORY SPECIFICATIONS

ITEM SPECIFICATION
Memory Size 4MB
Data Transfer 2,300 data points per second
Interval Mode 2 seconds to 1 day
Variable Rate Mode 16 user-programmable sampling rates
Time Format Month / day / year Hour / minute / second
Memory Full Behaviour “Wrap around” or “fill & stop” option

 

DT2011B: Single Channel Vibrating Wire Data Logger is commonly used where reliable, unattended monitoring of a single vibrating wire sensor including piezometers, crack meters and strain gauges is required.

View illustrations on how this is used for:

DT2011B Ordering Info

ITEM PART #
DT2011B Single Channel Vibrating Wire Data Logger DT2011B
Cable Gland Nut Wrench DT100
Pole Mount Kit DT20XX-M1
4” Secondary Enclosure DT2011-SE

Options

RSTAR L900 – automated wireless data collection
DT2011B DTLINK – wireless data collection

File Name

DT Series Dataloggers Installation Guidelines

Resource Type

Manual
Language Version Download
English ELM0089B

File Name

DT Series Dataloggers Maintenance and Service Guidelines

Resource Type

Manual
Language Version Download
English ELM0088B

File Name

DT Logger Host Instruction Manual PC Platform

Resource Type

Manual
Language Version Download
English ELM0080R

File Name

DT Logger Host Instruction Manual – Mobile Platform

Resource Type

Manual
Language Version Download
English ELM0081D

File Name

DT2011B Single Channel Vibrating Wire Data Logger

Resource Type

Brochure
Language Version Download
English ELB0016Y
Portuguese ELB0089A
Spanish ELB0083B

File Name

Firmware Updates for PC (Logger Firmware Update.exe)

Resource Type

Software

Note

The following loggers firmware can be updated using this utility:
DT2011, DT2011B, DT2055B, DT2040, DT4205, RTU, DTL201B, DT2485, DT2350, GAA2820, DTSAA

Only download and install the firmware for your device if you have been instructed by a representative from RST Instruments Ltd. Any unnecessary installation of the firmware can cause unexpected device behaviour.

Please contact RST Technical Support for more information:
Email: support@rstinstruments.com
Telephone: 604-540-1100

Language Version Download
English 1.25

File Name

DT Logger Host Software for PC

Resource Type

Software

Note

Unzip the ZIP file once it is downloaded.
From the extracted files, double click on the “.exe” file.
Follow the instructions to install.

Language Version Download
English 1.20.0
English Release Notes

File Name

DT Logger Host Software for Nautiz X8

Resource Type

Software
Language Version Download
English 2.70

File Name

DT Logger Host for FieldPC

Resource Type

Software

Note

INSTALLATION NOTES:
Unzip the ZIP file once it is downloaded.
From the extracted files, open file titled “Installing Mobile DT Logger Host Software.txt”.
Follow instructions in the file.

Language Version Download
English 2.67

File Name

8-inch Secondary Enclosure Installation Guide

Resource Type

Installation Guide
Language Version Download
English ELI0095A

Speak with an Expert

I’m very happy with the quality of the instrumentation and technical support from RST, as always. They worked with us from the initial stages of the project to ensure that we were fully prepared and equipped to use the RSTAR network for the first time. They delivered everything within the tight project time frame to ensure that there were no delays on site, and the submersible tilt meters looked like new even after over twelve months of being submerged in Thames water!
 
-Richard Lipscombe, BEng (Hons), Director & Principle Consultant - RL Geotechnical Ltd