File Name
In-Place Tiltmeter
Resource Type
BrochureLanguage | Version | Download |
---|---|---|
English | ICB7750 |
RST’s In-Place Tiltmeters (MEMS) measure tilt in two axial planes perpendicular to the surface of the base plate. The unit is intended to be permanently installed to provide long-term observation with maximum resolution and sensitivity, and is conveniently designed for manual monitoring or remote data acquisition.
RST’s In-Place Tiltmeters (MEMS) measure tilt in two axial planes perpendicular to the surface of the base plate. The unit is intended to be permanently installed to provide long term observation with maximum resolution and sensitivity, and is conveniently designed for manual monitoring or remote data acquisition. The system consists of a tiltmeter mounting plate, interconnecting cable, and data logger or readout instrument. The electronics are housed in a NEMA 4X (IP-65) enclosure for environmental protection, and is typically bolted or bonded to the structure. For maximum resistance against water ingress, the cable is typically hard wired to the enclosure. The interconnecting cable is suitable for direct burial.
ITEM | SPECIFICATION |
Range | ±30° |
Resolution | 0.0002° (0.004° mm/m) |
Sensor Precision | ±0.0013° (0.02 mm/m)¹ ±0.0005° (0.01 mm/m)² |
Sensor 24 h Stability | ±0.03 mm/m¹ ±0.01 mm/m² |
Sensor | MEMS (Micro-Electro-Mechanical Systems) Accelerometer |
Temperature Dependent Uncertainty | ± 0.016 mm/m/°C (±0.001°/°C) , for ± 5° from vertical ± 0.033 mm/m/°C (±0.002°/°C) , for ± 15° from vertical |
Temperature Accuracy | ± 0.5 °C (0°C to 60°C) ± 1.0 °C (-40°C to 60°C) |
Temperature Resolution | 0.06 °C |
Operating Temperature | -40 to 60°C (-40 to 140°F) |
Dimensions | 80 x 80 x 61mm (3.15 x 3.15 x 2.4 in.) |
¹: 99% Confidence Interval ²: 68% Confidence Interval |
In-Place Tiltmeters are commonly used for:
BIAXIAL | PART # |
MEMS Biaxial Tiltmeter – digital bus output | IC6656B |
MOUNTING | PART # |
MEMS Tiltmeter Horizontal Mounting Plate | IC6700 |
MEMS Tiltmeter Vertical Mounting Bracket | IC6705 |
TEMPERATURE MEASUREMENT | |
Included | |
READOUTS & DATA LOGGERS | PART # |
Rugged Handheld PC | IC32000-NAUTIZ |
Digital Interface for Rugged Handheld PC with software |
ELGL4010 |
DT2485 DT-BUS Data Logger | DT2485 |
FlexDAQ Dataloggers | |
RSTAR Affinity Data Logger |
CABLE ORDERING | |
ITEM | DESCRIPTION |
EL380004 | Two twisted pairs cable with polyurethane jacket |
ELECTRICAL | |
Supply Voltage | 5 to 15V DC |
Operating Current | 490 uA (Reading Average, per sensor) |
Standby Current | <20uA (per sensor) |
Signal Output | RS485 Digital Bus (MODBUS RTU Protocol) |
I’m very happy with the quality of the instrumentation and technical support from RST, as always. They worked with us from the initial stages of the project to ensure that we were fully prepared and equipped to use the RSTAR network for the first time. They delivered everything within the tight project time frame to ensure that there were no delays on site, and the submersible tilt meters looked like new even after over twelve months of being submerged in Thames water!
-Richard Lipscombe, BEng (Hons), Director & Principle Consultant - RL Geotechnical Ltd